Industrial Data Solutions® — Industrial EthernetCategory 5e DataTuff® CablesCategory 5e • Unshielded • 4-Pair• Compatible with Belden Metal Body RJ45 Plugs R301601 and R301602• Bonded Pairs
| Part Number | AWG | Description | OD (Nom.) | Jacket Thickness | ||
| Inch | mm | Inch | mm | |||
| Solid BC Conductors • Polyolefin Insulation • PVC Jacket | ||||||
| 7923A | 24 | -40 to +75°C EtherNet/IP Compliant MSHA Approved NEC: CMR, CMX-Outdoor • CEC: CMR FT4 Sunlight and Oil Resistant Bonded Pairs | 0.23 | 5.84 | 0.03 | 0.76 |
| 7922A | 22 | -25 to +75°C UL PLTC -25 to +75 NEC: CMR, CMX-Outdoor • CEC: CMR FT4 Sunlight and Oil Resistant Bonded Pairs | 0.301 | 7.65 | 0.03 | 0.76 |
| 7918A | 24 | -40 to +75°C MSHA Approved* NEC: CMR, CMX-Outdoor • CEC: CMR FT4 Sunlight and Oil Resistant | 0.23 | 5.84 | 0.03 | 0.76 |
| Solid BC Conductors • Polyolefin Insulation • PVC Inner and Outer Jackets | ||||||
| 11700A | 24 | -40 to +75°C Upjacketed EtherNet/IP Compliant MSHA Approved* NEC: CMR, CMX-Outdoor • CEC: CMR FT4 Sunlight and Oil Resistant Bonded Pairs | 0.285 | 7.24 | 0.035 | 0.89 |
| 11700A2 | 24 | -10 to +75°C Upjacketed Oil Res I/II NEC: CMR • CEC: CMR FT4 Sunlight and Oil Resistant Bonded Pairs | 0.285 | 7.24 | 0.035 | 0.89 |
| Solid BC Conductors • Polyolefin Insulation • PVC Inner Jacket • Interlocked Aluminum Armor • PVC Outer Jacket | ||||||
| 121700A | 24 | -40 to +75°C Armored NEC: CM • CEC: HL, CMG FT4 Sunlight and Oil Resistant Bonded Pairs | 0.53 | 13.46 | 0.045 | 1.14 |
| 121700R | 24 | -40 to +75°C Armored -40°C Cold Impact NEC: CM • CEC: HL, CMG FT4 Sunlight and Oil Resistant Bonded Pairs | 0.53 | 13.46 | 0.045 | 1.14 |
| Stranded (7 x 32) TC Conductors • Polyolefin Insulation • PVC Jacket | ||||||
| 7924A | 24 | -40 to +75°C Flexible NEC: CMR, CMX-Outdoor • CEC: CMR FT4 Sunlight and Oil Resistant Bonded Pairs | 0.242 | 5.84 | 0.03 | 0.76 |
| Stranded (7 x 32) TC Conductors • Polyolefin Insulation • PVC Jacket | ||||||
| 7930A | 24 | -25 to +75°C Flexible NEC: CMR, CMX-Outdoor • CEC: CMR FT4 Sunlight and Oil Resistant | 0.242 | 5.84 | 0.03 | 0.76 |
| Solid BC Conductors • Polyolefin Insulation • Polyethylene Jacket | ||||||
| 7934A | 24 | -40 to +75°C Waterblocked Burial Halogen Free EtherNet/IP Compliant Sunlight and Oil Resistant Bonded Pairs | 0.23 | 5.84 | 0.03 | 0.76 |
| Solid BC Conductors • Polyolefin Insulation • LSZH Jacket | ||||||
| 7935A | 24 | -40 to +75°C Low Smoke, Halogen Free EtherNet/IP Compliant NEC: CM • CEC: CM FT1 Sunlight Resistant Bonded Pairs | 0.23 | 5.84 | 0.03 | 0.76 |
| Solid BC Conductors • FEP Insulation • FEP Insulation | ||||||
| 7928A | 24 | -70 to +150°C High and Low Temp EtherNet/IP Compliant NEC: CMP • CEC: CMP FT6 Oil Res I/II • Gas Res Sunlight and Oil Resistant Bonded Pairs | 0.187 | 4.75 | 0.03 | 0.76 |