SIMpull THHN/THWN-2 Copper SPEC 10000 Southwire

SOUTHWIRE 规格书下载

600 Volts. Copper Conductor. PVC Insulation/Nylon Sheath THHN/THWN-2. Heat, Moisture, Gasoline and Oil Resistant II. SIMpull® Technology for Easier Pulling.

CONSTRUCTION:

1.      Conductor: Sizes 8 - 3/0 AWG use a stranded combination-unilay soft drawn annealed bare copper per ASTM B3 and B787. Sizes 4/0 AWG and larger use a stranded compressed annealed bare copper per ASTM B3 and B8.

2.      Insulation: Heat and moisture resistant Polyvinyl Chloride (PVC)

3.      Sheath: Nylon jacket utilizing SIMpull® Technology

APPLICATIONS AND FEATURES:

Southwire SIMpull® THHN/THWN-2 copper conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code® and other applicable codes and standards. Voltage for all applications is 600 volts. SIMpull® THHN/THWN-2 copper conductors are designed to be installed without the application of a pulling lubricant. These conductors have multiple ratings depending upon the product application. Allowable temperatures are as follows:

THHN or T90 Nylon: Dry locations not to exceed 90°C

THWN-2: Wet or dry locations not to exceed 90° C or locations not to exceed 75°C when exposed to oil

TWN75: Wet locations not to exceed 75°C

MTW: Wet locations or when exposed to oil at temperatures not to exceed 60°C or dry locations not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79)

AWM: Dry locations not to exceed 105°C only when rated and used as appliance wiring material

 

FEATURES

Sunlight resistant: 8 AWG and larger

Gasoline and Oil Resistant II

CT Rated: 1/0 AWG and larger

VW-1: All Sizes

FT-1: All Sizes

AWM: Sizes 14 through 6 AWG

MTW: Stranded Constructions Only

RoHS Compliant

LEED v4.1: Materials & Resources Credit MRc6; PBT (Lead Content Below 300 ppm Threshold)

 

SPECIFICATIONS:

  ASTM B3 Soft or Annealed Copper Wire

  ASTM B8 Concentric-Lay-Stranded Copper Conductors

  ASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors

  UL 83 Thermoplastic Insulated Wires and Cables

  UL 758 Standard for Appliance Wiring Material

  UL 1063 Machine Tool Wiring (MTW)

  UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)

  CSA C22.2 No. 75 Thermoplastic Insulated Wires and Cables

  ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy

  Federal Specication A-A-59544

  NMX-J-010-ANCE Thermoplastic insulated wires and cables

  NOM-063-SCFI Electrical Products Conductors Safety Requirements

  NEMA 70901-2-2024 Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable


Cond.   Size Strand Count Diameter Over Conductor Insul. Thickness Insulation Color Jacket Thickness Approx. OD Copper Weight Approx. Weight
AWG/KcmilNo. of Strandsinchmil
milinchlb/1000ftlb/1000ft
8190.14130TN50.2175063
2190.28641TN70.384204235
4190.22540PK50.324128154
1190.32250GN/YW50.441258302
2/0190.40550GY/PE50.524410466
4/0190.51250GN/PE50.627653719
300370.6160TN50.7369261005
400370.70560PK50.82712351323
600610.86570PK101.00418521969
1000611.11770BK101.28130873264