+86 138 6133 0396
sales@acebat-elec.com

控制线

THHN/THWN Copper Silicone-Free

SOUTHWIRE 规格书下载

600 Volts. Copper Conductor. PVC Insulation/Nylon Sheath THHN/THWN. Heat, Moisture, Gasoline and Oil Resistant II.Silicone-Free.

CONSTRUCTION:

1.      Conductor: Solid sizes 14 - 10 AWG use soft drawn annealed bare copper per ASTM B3. Stranded sizes 14 - 10 AWG use combination-unilay soft drawn annealed bare copper per ASTM B3 and B787.

2.      Insulation: Heat and moisture resistant Polyvinyl Chloride (PVC)

3.      Sheath: Nylon

 

APPLICATIONS AND FEATURES:

APPLICATION

Southwire THHN copper conductors are primarily used in conduit for branch circuits in commercial or industrial applications as specified in the National Electrical Code® and other applicable codes and standards. Voltage for all applications is 600 volts. These conductors have multiple ratings depending upon the product application. Allowable temperatures are as follows:

THHN or T90 Nylon: Dry locations not to exceed 90°C

  THWN: Wet locations not to exceed 75°C or dry locations not to exceed 90°C or locations not to exceed 75°C when exposed to oil

TWN75: Wet locations not to exceed 75°C

MTW: Wet locations or when exposed to oil at temperatures not to exceed 60°C or dry locations not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79)

AWM: Dry locations not to exceed 105°C only when rated and used as appliance wiring material

 

FEATURES

Gasoline and Oil Resistant II

VW-1: Sizes 14 through 10 AWG

FT1: All Sizes

AWM: Sizes 14 through 10 AWG

MTW: Stranded Constructions Only

RoHS Compliant

 

SPECIFICATIONS:

  ASTM B3 Soft or Annealed Copper Wire

  ASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors

  UL 83 Thermoplastic Insulated Wires and Cables

  UL 758 Standard for Appliance Wiring Material

  UL 1063 Machine Tool Wiring (MTW)

  CSA C22.2 No. 75 Thermoplastic Insulated Wires and Cables

  ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy

  Federal Specication A-A-59544

  NMX-J-010-ANCE Thermoplastic insulated wires and cables

  NOM-063-SCFI Electrical Products Conductors Safety Requirements

  NEMA 70901-2-2024 Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable


Cond. SizeMin Bending RadiusMax Pull Tension DC Resistance @   25°CAC Resistance   @75°C Inductive   Reactance @ 60HzAllowable Ampacity At 75°CAllowable Ampacity At 90°C
AWG/inchlbΩ/1000ftΩ/1000ftΩ/1000ftAmpAmp
Kcmil
140.4322.6313.170.0582025
120.5521.6622.0020.0542530
100.6831.041.2530.053540
140.5322.6313.170.0582025